X2M Cabinets
- Ultimate drying, storing & monitoring performance for MSD packages
- Ultra-low humidity storage technology to comply with J-STD-033B
- Turbo dryers with automatic regeneration for fast drying
Function:
- X2M-1200-6 is a plug and play, fully auto-dry cabinet which will be stable at ≦5%RH. There is no need to set the panel buttons at all. It is especially designed for moisture sensitive SMD packages to comply with J-STD-033B.
Features:
- Modular Design: This is a modularly designed dry cabinet. The main modules are display controller, power box, dehumidifier, shelf, caster wheel, cable, graph software, data logger and reader. All of the modules can be replaced easily.
- Green Design: The performance of the dry cabinet can be upgraded by just changing the modules. There will be no waste materials created to pollute the environment. The old modules can be collected and sent back to the maker. Dr. Storage dry cabinets can be used as long as the cabinet structure is in good condition. It means that the product life could last for 10 or 20 years. Thousands of our dry cabinets have been serving their owners for more than 10 years.
- Flexible Design: The users can choose to buy data loggers, or more dehumidifers in the beginning or can add these modules in future. The units are so flexible that users can select and install modules at any time.
- Easy Operation Design: The dry cabinet is used for the storage of Moisture Sensitive Devices at relative humidity of under 5%RH, which meets the requirements of J-STD-033B. It is a plug and play dry cabinet. Considerable training costs are saved.
- Data Recording: It is important to verify that the condition of storage meets the regulation of J-STD-033B. The users can connect note book PCs directly to the RS232 port of the cabinet to acquire the data or use our data logger to record the data. With our data recording function, the historical fluctuation of relative humidity and temperature can be shown clearly in the graph. The floor life of the Moisture Sensitive Devices can also be calculated in the software . This uniquely patented function can easily verify if the SMD packages are stored at proper condition. It is very convenient for those who carry out quality assurance procedures.
- Memo Cards: Special “Slash Door” design to allow inserting the memo cards which can record the necessary storage information of MSD management.
- Calibration Reminding: The drift effect of sensors might influence the accuracy. In order to help complying with the regulation of ISO, a unique design of calibration expiration reminding function is offered in this model. When the sensor runs over 365 days, the decimal point in the panel will be flashed for reminding the user.
- Alert Setting: There are two ways of alert – flash and buzz. Alert can be activated when the relative humidity or temperature is higher than the setting of upper limit. And the flash and buzz alert can be activated by different delay time.
Dry Box Specifications | |||||||
Model | X2M-157 | X2M-200 | X2M-315 | X2M-400 | X2M-575 | X2M-600 | X2M-1200-6 |
Internal Capacity |
6 cu ft. |
7 cu ft |
12 cu ft. |
15 cu ft. | 21 cu ft. | 22 cu ft. | 44 cu ft. |
165 L | 202 L | 334 L | 413 L | 607 L | 624 L | 1250 L | |
External Size LxWxH |
17.5 x 18 x 41(in) | 23.5 x 26.5 x 25(in) |
35.5 x 18 x 41(in) |
23.5 x 26.5 x 50 (in) | 35.5 x 31.5 x 41(in) | 23.5 x 26.5 x 71.5(in) |
47 x 26.5 x 71.5(in) |
450 x 452 x 1045 (mm) | 600 x 672 x 632 (mm) | 905 x 452 x 1045 (mm) | 600 x 672 x 1274 (mm) | 905 x 800 x 1045 (mm) | 600 x 672 x 1820 (mm) | 1200 x 672 1820 (mm) | |
Internal Size LxWxH |
17.5 x 16.5 x 34 (in) | 23.5 x 25 x 20.5 (in) | 35.5 x 16.5 x 34 (in) | 23.5 x 30 x 47.5 (in) | 35.5 x 30.5 x 34 (in) | 23.5 x 25 x 63.5 (in) | 47 x 26.5 x 63.5 (in) |
No. of Shelves | 3 Adjustable | 2 Adjustable | 3 Adjustable | 3 Adjustable | 3 Adjustable | 5 Adjustable | 5 Adjustable |
Shelf adjustability |
On 30 cm centers | ||||||
Electrical Requirements | 110V | ||||||
Data Software | Included | ||||||
Data Logger | Optional | ||||||
Data Reader | Optional | ||||||
Nitrogen Dry Modules (QDN) | Optional |